Switches: ST22445-1, ST25004, ST26K

Get a Quote

 
MFG SKUNSNItem NameDetailsManufacturer (CAGE)RFQ
ST22445-1
ST224451
5930-00-458-4689Switch unit, solid StateGeneral Characteristics Item Description: Spst normally open, 120.0 V, 5 amp max rms load current, 2 V max on voltage, 0.1 ma max switch current, 1 millisecond turn on time, 0 deg F min and 120.00 deg F ambient temp, 50 to 60 cps operating freq, 2 ma leakage current, 50 amps for 15 milliseconds inrush current, less than 100 ua at 9 V required to actuate unit, 5 no. 6-32 binding posts, 3.125 in. lg, 2.625 in. W, 2.250 in. H, two 0.219 in. dia mtg holes on 3 in. mtg centers
Gems Sensors Inc. (04034)

Quote

ST22731-001
ST22731001
5930-00-683-1628Switch, ToggleThread Class: 2A
Body Style: Bushing mount
Overall Length: 1.270 inches maximum
Mbda UK LTD (K0967)

Quote

ST22K 5930-00-655-1507Switch, ToggleThread Class: 2A
Body Style: Bushing mount
Overall Length: 1.281 inches maximum
Joint Army-Navy Specifications (81350)
Military Specifications (81349)

Quote

ST22K 5930-01-124-7019Switch, ToggleThe Technical Material Corporation (82679)

Quote

ST22M 5930-00-661-0995Switch, ToggleMounting Method: Threaded bushing
Overall Length: 1.281 inches maximum
Nonpile-up Contact Arrangement: 2 pole, single throw, normally open, momentary action single switch unit
Cooper Industries Inc. (04009)

Quote

ST-22-N
ST22N
5930-00-655-1508Switch, ToggleThread Class: 2A
Body Style: Bushing mount
Overall Length: 1.281 inches maximum
Cooper Industries Inc. (04009)

Quote

ST22N 5930-00-274-5118Switch, ToggleNonpile-up Contact Arrangement: 2 pole, double throw, both positions maintained single switch unit
Inclosure Type: Fully inclosed
Nominal Thread Size: 0.469 inches
Eaton Corp. (55459)
Eaton Electrical Inc. (55588)

Quote

ST22N 5930-00-581-0412Switch, ToggleNonpile-up Contact Arrangement: 2 pole, double throw, both positions maintained single switch unit
Terminal Type and Quantity: 6 tab, solder lug
Body Length: 1.281 inches nominal
Joint Army-Navy Specifications (81350)

Quote

ST22N 5930-00-655-1508Switch, ToggleThread Class: 2A
Body Style: Bushing mount
Overall Length: 1.281 inches maximum
Eaton Corp. (15605)
Eaton Electrical Inc. (55588)
LEE Co., The (31356)

Quote

ST22N 5930-01-011-4775Switch, ToggleSwitch Actuator Quantity: 1
Dialight Corporation (83330)

Quote

ST22NJBT 5930-00-655-1508Switch, ToggleThread Class: 2A
Body Style: Bushing mount
Overall Length: 1.281 inches maximum
Eaton Corporation (81640)

Quote

ST22R 5930-00-902-3486Switch, ToggleMounting Method: Threaded bushing
Nonpile-up Contact Arrangement: 2 pole, double throw, one position momentary single switch unit
Inclosure Type: Fully inclosed
Eaton Corp. (55459)
Eaton Electrical Inc. (55588)

Quote

ST2-3F1
ST23F1
5930-01-038-7960Switch, ToggleMounting Method: Threaded bushing
Overall Length: 0.500 inches nominal
Nonpile-up Contact Arrangement: 2 pole, double throw, two positions momentary single switch unit
Mors Components Inc. (54659)

Quote

ST2-3F1MZQ
ST23F1MZQ
5930-01-038-7960Switch, ToggleMounting Method: Threaded bushing
Overall Length: 0.500 inches nominal
Nonpile-up Contact Arrangement: 2 pole, double throw, two positions momentary single switch unit
Mors Components Inc. (54659)

Quote

ST23K 5930-00-050-2639Switch, ToggleNonpile-up Contact Arrangement: 1 two circuit, both positions maintained single switch unit
Terminal Type and Quantity: 4 tab, solder lug
Switch Actuator Quantity: 1
Joint Army-Navy Specifications (81350)

Quote

ST23N 5930-00-525-1232Switch, ToggleNonpile-up Contact Arrangement: 2 two circuit, both positions maintained single switch unit
Inclosure Type: Fully inclosed
Nominal Thread Size: 0.469 inches
Military Specifications (81349)

Quote

ST2-4
ST24
5930-01-054-3868Switch, ToggleNonpile-up Contact Arrangement: 2 pole, double throw, one position momentary, two positions maintained single switch unit
Inclosure Type: Fully inclosed
Nominal Thread Size: 0.250 inches
Mors Components Inc. (54659)

Quote

ST2-4F1A168P1
ST24F1A168P1
5930-01-123-9362Switch, ToggleMounting Method: Threaded bushing
Overall Length: 0.500 inches nominal
Nonpile-up Contact Arrangement: 2 pole, double throw, three positions maintained single switch unit
Mors Components Inc. (54659)

Quote

ST25004 5930-01-360-8110Switch AssemblyAdmiral Filter Company LLC (25204)
Shimadzu Scientific Instruments Inc. (1T422)

Quote

ST-25872
ST25872
5930-01-018-1687Switch, solid StateGems Sensors Inc. (04034)

Quote

ST26068 5930-00-857-5056Switch, SensitiveNonpile-up Contact Arrangement: 1 pole, double throw, one position momentary single switch unit
Inclosure Type: Fully inclosed
Maximum Voltage Rating in Volts: 28.0 dc
Lockheed Martin Corporation (04236)

Quote

ST26068-1
ST260681
5930-00-857-5056Switch, SensitiveNonpile-up Contact Arrangement: 1 pole, double throw, one position momentary single switch unit
Inclosure Type: Fully inclosed
Maximum Voltage Rating in Volts: 28.0 dc
Lockheed Martin Corporation (04236)

Quote

ST262-1
ST2621
5930-00-459-4392Switch, ThermostaticMounting Method: Bracket and threaded hole
Nonpile-up Contact Arrangement: 1 pole, single throw, normally closed, momentary action
Terminal Type: Quick disconnect, male
Alliance Laundry Systems LLC (59618)

Quote

ST26K 5930-00-050-2649Switch, ToggleNonpile-up Contact Arrangement: 2 pole, single throw, both positions maintained single switch unit
Inclosure Type: Fully inclosed
Nominal Thread Size: 0.469 inches
Joint Army-Navy Specifications (81350)

Quote

  • We solve sourcing challenges for ST22445-1, ST22NJBT, ST22R, ST23K, ST23N, ST2-4F1A168P1, ST-25872, ST26068, ST262-1, ST26K - NSN parts, hard to find, long lead time and obsolete components.